Using a urodynamic technique, vesicourethral function was evaluated in 30 patients who had undergone surgery for uterine cancer. In all 28 patients treated with radical hysterectomy, detrusor function was damaged irrespective of the use of the Cavitron ultrasonic surgical aspirator (CUSA), whereas, in 2 patients treated with semiradical hysterectomy, the function was preserved. Vesicourethral functions 3 weeks after the operation in all 28 patients treated with radical hysterectomy showed underactive detrusor function with low compliance. In 10 out of these 28 patients, postoperative maximum urethral closure pressure (MUCP) did not decrease, without relation to the use of CUSA nor to the presence of detrusor sphincter dyssynergia, and more than 5 weeks were required to reduce residual urine to less than 50 ml. On the other hand, in the remaining 18 patients, postoperative MUCP decreased, and residual urine decreased to less than 50 ml by 5 weeks after the operation. From the results obtained here, we can conclude that the evaluation of MUCP at an early phase after the operation is a useful tool to predict complications caused by residual urine, such as urinary tract infection, irreversible alteration of detrusor function or deterioration in renal function.

This content is only available via PDF.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.